Latest Refractory Personnel API-936 Exam Questions

Dec 07,2022
Testpassport Refractory Personnel API-936 Exam Questions cover the complete exam, if you want to pass API-936 exam, then you might get the ideal API Certification Questions and Answers from Testpassport. The latest Testpassport in the API Refractory Personnel certification preparation materials, which can be tested by API. Refractory Personnel API-936 Exam Questions not only covers all topics of API Refractory Personnel exam, but also gives you a chance to learn more skills. These API API-936 covers every topic of the exam syllabus, so you only need to prepare and pass Testpassport API-936 certification exam, then you also can pass real API-936 exam at high passing score. 
Refractory Personnel API-936 Exam

API 936 - Refractory Personnel

The API 936 Refractory Personnel certification is designed to identify candidates possessing the knowledge of API STD 936 Refractory Installation Quality Control Guidelines. These are guidelines for the installation quality control of monolithic refractory linings and may be used to supplement owner specifications.

API 936 certification raises the bar of competence for qualified personnel, who must have knowledge of installation, inspection, testing and repair of refractory linings. It provides the industry with a prequalified set of individuals prepared for the job and readily identifies those who are qualified to do the job. This exam can now be scheduled either at in-person test centers or through remote proctoring. API 936 certification is valid for a three-year term.

Exam Information
The API 936 exam is 3.25 hours long.
There are 85 questions, of which only 75 are scored. The remaining 10 are pretest, which are not scored. 
All questions are multiple-choice and closed-book. 
This exam has a set passing scaled score. 

API API-936 exam questions are collected by Testpassport professional API certified experts, which can guarantee the accuracy of API-936 real exam questions. Share Refractory Personnel API-936 Demo Questions
1.As installed testing is the terminology for testing refractory that was sampled during installation in order
to confirm that they meet specified.
A. Physical property standards
B. Chemical property standards
C. Both as above
D. None of the above
Answer: A

2. Arrange for testing at either an independent laboratory or the manufacturer’s plant is
A. Owner responsibility
B. Inspector responsibility
C. Contractor responsibility
D. Manufacturer responsibility
Answer: C

3. Testing frequency for material qualification of refractory for other services requires
A. 1 sample per pallet or less from each production run
B. 1 sample per 3 pallets or less from each production run
C. 1 sample per 3 pallets or more from each production run
D. None of the above
Answer: B

4.Refractories containing a substantial amount of silica which is reactive with basic refractories, basic slags, or basic fluxes at high temperatures are known as
A. Acid refractories
B. Basic refractories
C. Natural refecatories
D. None of the above
Answer: A

5.The vessel downstream of the reactor used to separate different product fractions is called
A. Standpipe of FCCU
B. Transfer line of FCCU
C. Fractionator of FCCU
D. None of the above
Answer: C

6. The vessel in which coke and residual hydrocarbons are burned off the catalyst and the flue gas is then
separated from the catalyst is called
A. Reactor of FCCU
B. Regenerator of FCCU
C. Cyclones of FCCU
D. None of the above
Answer: B